Lif12YC11Y
PUR Servo Cables
for trailing chains
Construction
A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation modified polyester (TPE-E)
B Identification power conductors black with printing U / L1 / C / L+, V / L2 resp.
B W / L3 / D / L-, green/yellow
B control conductors black number coded 5 - 8 for two pair con-
B struction, with printing BR1 resp. BR2 for one pair construction
C Pair screen polyester coated aluminium foil
C tinned copper spiral, coverage approx. 95%
D Pair jacket special thermoplastic compound
E Central filler flexible synthetic rope as strain relief
E Cabling power conductors and pair(s) cabled in a concentric layer
F Lateral filler flexible synthetic rope
G Taping polyester fleece
H Screen tinned copper braid, coverage approx. 85%
I Taping polyester fleece
J Jacket polyurethane, matte finish
J Colour orange RAL 2003
Lif12YC11Y
![Lif12YC11Y -[GCE Cables -Italy]](/images/stories/cables/Special_Cables_for_Factory_Automation/Lif12YC11Y_2.jpg)
![Lif12YC11Y -[GCE Cables -Italy]](/images/stories/cables/Special_Cables_for_Factory_Automation/Lif12YC11Y_3.jpg)
Technical Data
Conductor resistance R 0,75 mm2 < 26,0 Ohm/km
1,00 mm2 < 19,5 Ohm/km
1,50 mm2 < 13,3 Ohm/km
2,50 mm2 < 7,98 Ohm/km
4,00 mm2 < 4,95 Ohm/km
6,00 mm2 < 3,30 Ohm/km
Insulation resistance RI > 100 MOhm x km
Transfer impedance ZT < 250 mOhm/m
Operating voltage U0/U 0,6/1 kV (power conductors)
U0/U 300/500 V (control conductors)
Test voltage UT 4 kV (power conductors)
2 kV (control conductors)
Bending radius rmin. 10 x cable diameter
Travelling speed vmax.
freely moving 10 m/s 10 m/s 10 m/s
sliding 5 m/s 5 m/s 5 m/s
Acceleration amax. 2 m/s2 4 m/s2 10 m/s2
Bending cycles at a travelling distance of 7 m
10 mio. 5 mio. 2 mio.
Temperature range
mobile application - 40 °C up to + 80 °C
fixed installation - 50 °C up to + 80 °C
Oil resistance HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance HD 22.10
Ozone resistance HD 22.2
Flame retardance IEC 60332-1, EN 50265-2-1
Halogen content IEC 60754-1
Corrosivity IEC 60754-2
Smoke density IEC 61034, EN 50268-2 LT > 60%
Options
- other core configurations and cross
sections manufactured upon request - PUR trailing cables
low capacitance versions
without inner jacket - PUR trailing cables
without inner jacket - PVC installation cables

Last Updated (Monday, 20 June 2011 10:27)