Li2YH DIN
LSZH Electronics Cables
Construction
A Conductor flexible bare copper as per VDE 0812 resp. IEC 60228 class 5
B Insulation PE compound type 2Y as per DIN VDE 0207 part 23
B Identification colour code as per DIN 47100 (with repetition of colours as of the 45th core)
C Central filler (where applicable) extruded dummy element or flexible synthetic rope
C Cabling conductors cabled in concentric layers
D Separator non hygroscopic talcum powder
E Jacket LSZH compound type TM7 as per DIN VDE 0281 part 24
E Colour grey RAL 7001
Li2YH DIN
![Li2YH DIN [GCE Cables - Italy]](/images/stories/cables/Electronics_Cables/Li2YH_DIN.jpg)
Technical Data
Conductor resistance R 0,14 mm2 < 138,0 Ohm/km
0,25 mm2 < 77,5 Ohm/km
0,34 mm2 < 56,0 Ohm/km
0,50 mm2 < 39,0 Ohm/km
0,75 mm2 < 26,0 Ohm/km
Insulation resistance RI > 20 MOhm x km
Operating capacitance C 0,14 mm2 < 90 pF/m
0,25 mm2 < 100 pF/m
0,34 mm2 < 110 pF/m
0,50 mm2 < 120 pF/m
0,75 mm2 < 120 pF/m
Operating voltage UB 350 V (peak) 0,14 mm2
500 V (peak) 0,25 mm2 & 0,34 mm2
U0/U 300/500 V as of 0,50 mm2
Test voltage UT 800 V 0,14 mm2
1200 V 0,25 mm2 & 0,34 mm2
3000 V as of 0,50 mm2
Bending radius rmin.
mobile application 10 x cable diameter
fixed installation 4 x cable diameter
Temperature range
mobile application - 15 °C up to + 70 °C
fixed installation - 40 °C up to + 70 °C
Flame retardance IEC 60332-1, EN 50265-2-1
Halogen content IEC 60754-1, EN 50267-2-1
Corrosivity IEC 60754-2, EN 50267-2-2
Toxicity index NES 713
Smoke density IEC 61034, EN 50268-2 LT > 60%
Last Updated (Tuesday, 09 November 2010 14:57)