PVC Control Cables
oil resistant

Construction

A Conductor flexible bare copper as per IEC 60228 class 5
B Insulation PVC compound type TI2
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
D Separator non hygroscopic talcum powder
E Jacket oil resistant PVC compound type TM5
E Colour grey RAL 7001

H05VV5-F  UL/CSA

H05VV5-F UL/CSA [GCE Cables - Italy]

Technical Data

Conductor resistance     R      0,50 mm2 < 39,0   Ohm/km
                                            0,75 mm2 < 26,0   Ohm/km
                                            1,00 mm2 < 19,5   Ohm/km
                                            1,50 mm2 < 13,3   Ohm/km
                                            2,50 mm2 <   7,98 Ohm/km
Insulation resistance     RI      > 20 MOhm x km
Nominal voltage            U0/U  300/500 V as per HAR
                                   U       600 V as per UL/CSA
Test voltage                 UT      3000 V

Bending radius             rmin.
mobile application                  12 x cable diameter
fixed installation                     4 x cable diameter

Max. admissible conductor temperature
        continuous                    +   70 °C
        in case of short circuit    + 150 °C

Temperature range
        mobile application          - 15 °C up to + 70 °C  as per HAR
                                                     up to + 90 °C  as per UL/CSA
        fixed installation             - 40 °C up to + 70 °C  as per HAR
                                                     up to + 90 °C  as per UL/CSA

Oil resistance                        HD 505.2.1 part 10, VDE 0472 part 803
                                            class B, UL 1581 part 50.182
Flame retardance                   IEC 60332-1, EN 50265-2-1,
                                            UL VW1, CSA FT1

Options

  • other core configurations, cross
    sections and jacket colours
    manufactured upon request
  • larger cross sections can be supplied
    only with UL/CSA approval as they are
    not included in HD 21.13 S1

 

 

Last Updated (Friday, 05 November 2010 15:52)