Interface Cables

Construction

A Conductor flexible bare copper as per VDE 0812
B Insulation medium density polyethylene
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Central filler (where applicable) flexible synthetic rope
D Cabling pairs cabled in concentric layers
E Taping polyester foil
F Drain wire tinned stranded copper
G Screen tinned copper braid, coverage approx. 85%
H Jacket polyurethane, shiny finish
H Colour grey RAL 7032

Li2YC11Y TP  DIN

Li2YC11Y TP DIN [GCE Cables - Italy]

Characteristic features

  • electronics cable       UB    350 V
  • capacitance              C       < 70 pF/m
  • inductance                L       approx. 0,66 mH/km
  • temperature range              - 5 °C up to + 70 °C (flexible use)
  • oil resistance                     HD 505.2.1, VDE 0472 part 803 A/B
  • hydrolysis resistance         HD 22.10
  • ozone resistance               HD 22.2

Last Updated (Wednesday, 10 November 2010 15:47)