LiYY UL DIN
PVC Electronics Cables
Construction
A Conductor flexible bare copper, concentrically
A stranded as per ASTM B 286
A AWG 26 - AWG 20 7 strands
A AWG 18 - AWG 16 19 strands
B Insulation semi-rigid PVC
B Identification colour code as per DIN 47100
C Central filler (where applicable)
C Cabling conductors cabled in concentric
C layers
D Separator non hygroscopic talcum powder
E Jacket special PVC compound type as per class 43
E Colour grey RAL 7001
LiYY UL DIN
![LiYY UL DIN - [GCE Cables-Italy] LiYY UL DIN - [GCE Cables-Italy]](/images/stories/cables/Electronics_Cables/LiYY_UL_DIN.jpg)
Technical Data
Conductor resistance R 0,14 mm2 26 AWG < 130,0 Ohm/km
0,23 mm2 24 AWG < 80,0 Ohm/km
0,35 mm2 22 AWG < 53,0 Ohm/km
0,56 mm2 20 AWG < 33,0 Ohm/km
0,96 mm2 18 AWG < 21,0 Ohm/km
1,30 mm2 16 AWG < 13,7 Ohm/km
Insulation resistance RI > 200 MOhm x km
Operating capacitance C 0,14 mm2 26 AWG < 90 pF/m
0,23 mm2 24 AWG < 100 pF/m
0,35 mm2 22 AWG < 110 pF/m
0,56 mm2 20 AWG < 120 pF/m
0,96 mm2 18 AWG < 120 pF/m
1,30 mm2 16 AWG < 120 pF/m
Operating voltage UB 300 V
Test voltage UT 1500 V
Bending radius rmin.
mobile application 10 x cable diameter
fixed installation 4 x cable diameter
Temperature range
mobile application - 15 °C up to + 80 °C
fixed installation - 40 °C up to + 80 °C
Flame retardance IEC 60332-1, EN 50265-2-1
Last Updated (Friday, 18 March 2011 16:55)