PVC Electronics Cables

Construction

A Conductor flexible bare copper, concentrically stranded as per ASTM B 286
A AWG 26 - AWG 20 7 strands
A AWG 18 - AWG 16 19 strands
B Insulation semi-rigid PVC
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Central filler (where applicable) flexible synthetic rope
D Cabling pairs cabled in concentric layers
E Taping polyester foil
F Drain wire tinned stranded copper
G Screen tinned copper braid, coverage approx. 85%
H Jacket special PVC compound type as per class 43
H Colour grey RAL 7032

LiYCY TP  UL DIN

LiYCY TP UL DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance   R    0,14 mm2 26 AWG < 130,0 Ohm/k
                                        0,23 mm2 24 AWG <   80,0 Ohm/k
                                        0,35 mm2 22 AWG <   53,0 Ohm/k
                                        0,56 mm2 20 AWG <   33,0 Ohm/k
                                        0,96 mm2 18 AWG <   21,0 Ohm/k
                                        1,30 mm2 16 AWG <   13,7 Ohm/k
Insulation resistance     RI   > 200 MOhm x km
Operating capacitance  C   0,14 mm2 26 AWG <   90 pF/m
                                        0,23 mm2 24 AWG < 100 pF/m
                                        0,35 mm2 22 AWG < 110 pF/m
                                        0,56 mm2 20 AWG < 120 pF/m
                                        0,96 mm2 18 AWG < 120 pF/m
                                        1,30 mm2 16 AWG < 120 pF/m
Transfer impedance     ZT    < 250 mOhm/m
Operating voltage        UB   300 V
Test voltage                UT   1500 V
Bending radius           rmin.
             mobile application 12 x cable diameter
             fixed installation    6 x cable diameter
Temperature range
            mobile application   - 15 °C up to + 80 °C
            fixed installation      - 40 °C up to + 80 °C
Flame retardance                IEC 60332-1, EN 50265-2-1

Oil Resistance                    UL 1581 and UL 758 and CSA C22.2, 210.2

Options

  • other core configurations and cross
    sections manufactured upon request 
  • low capacitance version
    UL/CSA approved 300 V  80 °C
    Li9YCY TP  UL DIN
  • low voltage computer cables
    UL approved 30 V  60 °C
    LiYCY TP  UL  LVCC
  • black outer jacket and core colour
    code as per VDE 0881 and IEC

 

 

Last Updated (Tuesday, 26 April 2011 11:03)