Li9Y(St)Y UL DIN
PVC Electronics Cables
low capacitance
Construction
A Conductor flexible bare copper, concentrically stranded as per ASTM B 286
A AWG 26 - AWG 20 7 strands
A AWG 18 - AWG 16 19 strands
B Insulation polypropylene
B Identification colour code as per DIN 47100
C Central filler (where applicable) flexible synthetic rope
C Cabling conductors cabled in concentric layers
D Drain wire tinned stranded copper
E Screen polyester coated aluminium foil
F Jacket special PVC compound type as per class 43
F Colour grey RAL 7001
Li9Y(St)Y UL DIN
![Li9Y(St)Y UL DIN - [GCE Cables - Italy]](/images/stories/cables/Electronics_Cables/Li9Y(ST)Y_UL_DIN.jpg)
Technical Data
Conductor resistance R 0,14 mm2 26 AWG < 130,0 Ohm/km
0,23 mm2 24 AWG < 80,0 Ohm/km
0,35 mm2 22 AWG < 53,0 Ohm/km
0,56 mm2 20 AWG < 33,0 Ohm/km
0,96 mm2 18 AWG < 21,0 Ohm/km
1,30 mm2 16 AWG < 13,7 Ohm/km
Insulation resistance RI > 1 GOhm x km
Operating capacitance C 0,14 mm2 26 AWG < 60 pF/m
0,23 mm2 24 AWG < 70 pF/m
0,35 mm2 22 AWG < 75 pF/m
0,56 mm2 20 AWG < 90 pF/m
0,96 mm2 18 AWG < 90 pF/m
1,30 mm2 16 AWG < 90 pF/m
Operating voltage UB 300 V
Test voltage UT 1500 V
Bending radius rmin.
mobile application 10 x cable diameter
fixed installation 4 x cable diameter
Temperature range
mobile application - 15 °C up to + 80 °C
fixed installation - 40 °C up to + 80 °C
Flame retardance IEC 60332-1, EN 50265-2-1
UL VW-1 and CSA FT1
Oil resistance UL 1581 and UL 758 and CSA C22.2, 210.2
Options
-
other core configurations and cross
sections manufactured upon request -
low voltage computer cables
UL approved 30 V 60 °C
LiYY UL LVCC - Low capacitance version
UL/CSA approved 300 V 80 °C
Li9YY UL DIN
- black outer jacket and
core colour code as per
VDE 0881 and IEC