Li9Y(St)CY TP UL DIN
PVC Electronics Cables
low capacitance
Construction
A Conductor flexible bare copper, concentrically stranded as per ASTM B 286
A (7 stranded construction)
B Insulation polypropylene
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Central filler (where applicable) flexible synthetic rope
D Cabling pairs cabled in concentric layers
E Screen polyester coated aluminium foil
F Drain wire tinned stranded copper
G Screen tinned copper braid, coverage approx. 85%
H Jacket special PVC compound type as per class 43
H Colour grey RAL 7032
Li9Y(St)CY TP UL DIN
![Li9Y(St)CY TP UL DIN - [GCE Cables - Italy] Li9Y(St)CY TP UL DIN - [GCE Cables - Italy]](/images/stories/cables/Electronics_Cables/Li9Y(ST)CY_TP_UL_DIN.jpg)
Technical Data
Conductor resistance R 0,14 mm2 26 AWG < 130,0 Ohm/km
0,23 mm2 24 AWG < 80,0 Ohm/km
0,35 mm2 22 AWG < 53,0 Ohm/km
Insulation resistance RI > 1 GOhm x km
Operating capacitance C 0,14 mm2 26 AWG < 60 pF/m
0,23 mm2 24 AWG < 70 pF/m
0,35 mm2 22 AWG < 75 pF/m
Transfer impedance ZT < 250 mOhm/m
Operating voltage UB 300 V
Test voltage UT 1500 V
Bending radius rmin.
mobile application 12 x cable diameter
fixed installation 6 x cable diameter
Temperature range
mobile application - 15 °C up to + 80 °C
fixed installation - 40 °C up to + 80 °C
Flame retardance IEC 60332-1, EN 50265-2-1
UL VW-1 and CSA FT1
Oil resistance UL 1581 and UL 758 and CSA C22.2, 210.2
Options
- other core configurations and cross
sections manufactured upon request - low capacitance version
UL/CSA approved 300 V 80 °C
Li9YY UL DIN - low voltage computer cables
UL approved 30 V 60 °C
LiYY UL LVCC - black outer jacket and
core colour code as per
VDE 0881 and IEC
Last Updated (Tuesday, 26 April 2011 11:31)