PVC Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation PVC compound type TI2 with enhanced properties
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Central filler (where applicable), no straight centre pair allowed
D Cabling pairs cabled in concentric layers
D lateral fillers admitted
E Taping polyester fleece
F Screen tinned copper braid, coverage approx. 85%
G Jacket PVC compound type TM2 with enhanced properties
G Colour grey RAL 7001

LifYCY  TP DIN

LifYCY TP DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance                 R            0,14 mm2 < 138,0 Ohm/km
                                                              0,25 mm2 <   77,5 Ohm/km
                                                              0,34 mm2 <   56,0 Ohm/km
                                                              0,50 mm2 <   39,0 Ohm/km
                                                              0,75 mm2 <   26,0 Ohm/km
                                                              1,00 mm2 <   19,5 Ohm/km
Insulation resistance                  RI           > 20 MOhm x km
Operating capacitance               C            0,14 mm2 <   90 pF/m
                                                              0,25 mm2 < 100 pF/m
                                                              0,34 mm2 < 110 pF/m
                                                              0,50 mm2 < 120 pF/m
                                                              0,75 mm2 < 120 pF/m
                                                              1,00 mm2 < 120 pF/m
Operating voltage                      UB           300 V
Test voltage                              UT           1500 V

Bending radius                          rmin.       12 x cable diameter
Travelling speed vmax.
        freely moving                                    4 m/s 4 m/s
        sliding                                              2 m/s 2 m/s
Acceleration                             amax.       2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
                                                               3 mio. 2 mio.

Temperature range
        mobile application                             -   5 °C up to + 80 °C
        fixed installation                                - 40 °C up to + 80 °C

Oil resistance                                           IEC 60811-2-1
Flame retardance                                      IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • jacket with improved oil resistance
    as per HD 505.2.1
    type designation   LifYCYö TP DIN
  • LSF version with improved behaviour
    under fire as per IEC 60332-3C
    type designation   LifYCYu TP DIN

 

Last Updated (Monday, 21 March 2011 10:29)