PVC Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation PVC compound type TI2 with enhanced properties
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket PVC compound type TM2 with enhanced properties
E Colour grey RAL 7001

LifYY ..Z

LifYY ..Z - [GCE Cables - Italy]

Technical Data

Conductor resistance                        R           0,50 mm2 < 39,0   Ohm/km
                                                                    0,75 mm2 < 26,0   Ohm/km
                                                                    1,00 mm2 < 19,5   Ohm/km
                                                                    1,50 mm2 < 13,3   Ohm/km
                                                                    2,50 mm2 <   7,98 Ohm/km
                                                                    4,00 mm2 <   4,95 Ohm/km
                                                                    6,00 mm2 <   3,30 Ohm/km
Insulation resistance                        RI           > 20 MOhm x km
Operating voltage                             U0/U       300/500 V
Test voltage                                     UT          2500 V

Bending radius                                 rmin.      10 x cable diameter
Travelling speed                               vmax.
        freely moving                                          4 m/s 4 m/s
        sliding                                                    2 m/s 2 m/s
Acceleration                                    amax.      2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
                                                                     3 mio. 2 mio.

Temperature range
        mobile application                                  -   5 °C up to + 80 °C
        fixed installation                                     - 40 °C up to + 80 °C

Oil resistance                                               IEC 60811-2-1

Flame retardance                                          IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • jacket with improved oil resistance
    as per HD 505.2.1
    type designation   LifYYö ..Z
  • LSF version with improved behaviour
    under fire as per IEC 60332-3C
    type designation   LifYYu ..Z

 

 

 

Last Updated (Monday, 21 March 2011 11:16)