LifYYCY ..Z
PVC Trailing Cables
Construction
A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation PVC compound type TI2 with enhanced properties
B Identification black number coded, green/yellow in the outer layer (JZ
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Inner jacket PVC compound type TM2 with enhanced properties
F Screen tinned copper braid, coverage approx. 85%
G Jacket PVC compound type TM2 with enhanced properties
G Colour grey RAL 7001
LifYYCY ..Z
![LifYYCY ..Z - [GCE Cables]](/images/stories/cables/Trailing_Cables_for_Cable_Chains/LIfYYCY..Z.jpg)
Technical Data
Conductor resistance R 0,50 mm2 < 39,0 Ohm/km
0,75 mm2 < 26,0 Ohm/km
1,00 mm2 < 19,5 Ohm/km
1,50 mm2 < 13,3 Ohm/km
2,50 mm2 < 7,98 Ohm/km
4,00 mm2 < 4,95 Ohm/km
6,00 mm2 < 3,30 Ohm/km
Insulation resistance RI > 20 MOhm x km
Operating voltage U0/U 300/500 V
Test voltage UT 2500 V
Bending radius rmin. 10 x cable diameter
Travelling speed vmax.
freely moving 4 m/s 4 m/s
sliding 2 m/s 2 m/s
Acceleration amax. 2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
3 mio. 2 mio.
Temperature range
mobile application - 5 °C up to + 80 °C
fixed installation - 40 °C up to + 80 °C
Oil resistance IEC 60811-2-1
Flame retardance IEC 60332-1, EN 50265-2-1
Options
- other core configurations and cross
sections manufactured upon request - jacket with improved oil resistance
as per HD 505.2.1
type designation LifYYCYö ..Z - LSF version with improved behaviour
under fire as per IEC 60332-3C
type designation LifYYCYu ..Z
Last Updated (Monday, 21 March 2011 11:49)