PVC Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation PVC compound type TI2 with enhanced properties
B Identification black number coded, green/yellow in the outer layer (JZ
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Inner jacket PVC compound type TM2 with enhanced properties
F Screen tinned copper braid, coverage approx. 85%
G Jacket PVC compound type TM2 with enhanced properties
G Colour grey RAL 7001

LifYYCY ..Z

LifYYCY ..Z - [GCE Cables]

Technical Data

Conductor resistance                    R            0,50 mm2 < 39,0   Ohm/km
                                                                 0,75 mm2 < 26,0   Ohm/km
                                                                 1,00 mm2 < 19,5   Ohm/km
                                                                 1,50 mm2 < 13,3   Ohm/km
                                                                 2,50 mm2 <  7,98  Ohm/km
                                                                 4,00 mm2 <  4,95  Ohm/km
                                                                 6,00 mm2 <  3,30  Ohm/km
Insulation resistance                    RI            > 20 MOhm x km
Operating voltage                         U0/U        300/500 V
Test voltage                                 UT           2500 V

Bending radius                            rmin.       10 x cable diameter
Travelling speed                          vmax.
        freely moving                                      4 m/s 4 m/s
        sliding                                                2 m/s 2 m/s
Acceleration                               amax.       2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
                                                                 3 mio. 2 mio.

Temperature range
        mobile application                               -   5 °C up to + 80 °C
        fixed installation                                  - 40 °C up to + 80 °C

Oil resistance                                             IEC 60811-2-1

Flame retardance                                        IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • jacket with improved oil resistance
    as per HD 505.2.1
    type designation   LifYYCYö ..Z
  • LSF version with improved behaviour
    under fire as per IEC 60332-3C
    type designation   LifYYCYu ..Z

 

 

 

 

Last Updated (Monday, 21 March 2011 11:49)