PVC Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation semi-rigid PVC
B Identification colour code as per DIN 47100
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket special PVC compound type as per class 43
E Colour grey RAL 7001

LifYY  UL DIN

LifYY UL DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance                          R             0,14 mm2 < 138,0 Ohm/km
                                                                        0,25 mm2 <   77,5 Ohm/km
                                                                        0,34 mm2 <   56,0 Ohm/km
Insulation resistance                           RI            > 200 MOhm x km
Operating capacitance                        C             0,14 mm2 <   90 pF/m
                                                                        0,25 mm2 < 100 pF/m
                                                                        0,34 mm2 < 110 pF/m
Operating voltage                               UB           300 V
Test voltage                                       UT           1500 V

Bending radius                                   rmin.       12 x cable diameter
Travelling speed                                 vmax.
        freely moving                                             4 m/s 4 m/s
        sliding                                                      2 m/s 2 m/s
Acceleration                                      amax.      2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
                                                                       3 mio. 2 mio.

Temperature range
         mobile application                                    -   5 °C up to + 80 °C
         fixed installation                                       - 40 °C up to + 80 °C

Oil resistance                                                   IEC 60811-2-1

Flame retardance                                              IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • black outer jacket
    type designation
    LifYY  UL DIN BK

 

 

 

 

Last Updated (Monday, 21 March 2011 15:32)