PVC Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation semi-rigid PVC
B Identification colour code as per DIN 47100
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Screen tinned copper braid, coverage approx. 85%
F Jacket special PVC compound type as per class 43
F Colour grey RAL 7001

LifYCY  UL DIN

LifYCY UL DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance                           R                0,14 mm2 < 138,0 Ohm/km
                                                                            0,25 mm2 <   77,5 Ohm/km
                                                                            0,34 mm2 <   56,0 Ohm/km
Insulation resistance                            RI               > 200 MOhm x km
Operating capacitance                         C                0,14 mm2 <   90 pF/m
                                                                            0,25 mm2 < 100 pF/m
                                                                            0,34 mm2 < 110 pF/m
Operating voltage                                UB               300 V
Test voltage                                        UT               1500 V

Bending radius                                    rmin.           12 x cable diameter
Travelling speed                                  vmax.
       freely moving                                                   4 m/s 4 m/s
       sliding                                                            2 m/s 2 m/s
Acceleration                                       amax.          2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
                                                                            2 mio. 1 mio.

Temperature range
         mobile application                                         -   5 °C up to + 80 °C
         fixed installation                                            - 40 °C up to + 80 °C

Oil resistance                                                        IEC 60811-2-1

Flame retardance                                                   IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • black outer jacket
    type designation
    LifYCY  UL DIN BK

 

 

Last Updated (Monday, 21 March 2011 16:25)