PVC Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation semi-rigid PVC
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Central filler (where applicable), no straight centre pair allowed
D Cabling pairs cabled in concentric layers
D lateral fillers admitted
E Taping polyester fleece
F Screen tinned copper braid, coverage approx. 85%
G Jacket special PVC compound type as per class 43
G Colour grey RAL 7001

LifYCY TP  UL DIN

LifYCY TP UL DIN -[GCE Cables - Italy]

Technical Data

Conductor resistance                      R                0,14 mm2 < 138,0 Ohm/km
                                                                       0,25 mm2 <   77,5 Ohm/km
                                                                       0,34 mm2 <   56,0 Ohm/km
                                                                       0,50 mm2 <   39,0 Ohm/km
                                                                       0,75 mm2 <   26,0 Ohm/km
                                                                       1,00 mm2 <   19,5 Ohm/km
Insulation resistance                       RI               > 200 MOhm x km
Operating capacitance                    C                0,14 mm2 <   90 pF/m
                                                                       0,25 mm2 < 100 pF/m
                                                                       0,34 mm2 < 110 pF/m
                                                                       0,50 mm2 < 120 pF/m
                                                                       0,75 mm2 < 120 pF/m
                                                                       1,00 mm2 < 120 pF/m
Operating voltage                           UB               300 V
Test voltage                                   UT               1500 V

Bending radius                               rmin.           12 x cable diameter
Travelling speed                             vmax.
        freely moving                                            4 m/s 4 m/s
        sliding                                                      2 m/s 2 m/s
Acceleration                                  amax.          2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
                                                                       3 mio. 2 mio.

Temperature range
        mobile application                                     -   5 °C up to + 80 °C
        fixed installation                                        - 40 °C up to + 80 °C

Oil resistance                                                  IEC 60811-2-1

Flame retardance                                             IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • black outer jacket
    type designation
    LifYCY  TP  UL DIN BK

 

 

Last Updated (Tuesday, 22 March 2011 09:43)