PVC Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation special PVC compound type as per class 43
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket special PVC compound type as per class 43
E Colour grey RAL 7001

LifYY  UL ..Z

LifYY UL ..Z - [GCE Cables - Italy]

Technical Data

Conductor resistance                      R               0,50 mm2 < 39,0   Ohm/km
                                                                      0,75 mm2 < 26,0   Ohm/km
                                                                      1,00 mm2 < 19,5   Ohm/km
                                                                      1,50 mm2 < 13,3   Ohm/km
                                                                      2,50 mm2 <   7,98 Ohm/km
                                                                      4,00 mm2 <   4,95 Ohm/km
                                                                      6,00 mm2 <   3,30 Ohm/km
Insulation resistance                       RI              > 20 MOhm x km
Operating voltage                           UB             600 V
Test voltage                                   UT             3000 V

Bending radius                               rmin.         10 x cable diameter
Travelling speed                             vmax.
       freely moving                                            4 m/s 4 m/s
       sliding                                                     2 m/s 2 m/s
Acceleration                                  amax.        2 m/s2 4 m/s2
Bending cycles at a travelling distance of 7 m
                                                                     3 mio. 2 mio.

Temperature range
        mobile application                                   -   5 °C up to + 80 °C
        fixed installation                                      - 40 °C up to + 80 °C

Oil resistance                                                 IEC 60811-2-1

Flame retardance                                           IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • slimline version 300 V  80 °C
    respectively 300 V  105 °C
    UL/CSA approved
  • black outer jacket
    type designation
    LifYY  UL ..Z BK

 

 

Last Updated (Wednesday, 23 March 2011 14:54)