PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation polypropylene
B Identification colour code as per DIN 47100
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001

Lif9Y11Y DIN

Lif9Y11Y DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance                          R                 0,14 mm2 < 138,0 Ohm/km
                                                                            0,25 mm2 <   77,5 Ohm/km
                                                                            0,34 mm2 <   56,0 Ohm/km
Insulation resistance                           RI                 > 1 GOhm x km
Operating capacitance                        C                 0,14 mm2 < 60 pF/m
                                                                            0,25 mm2 < 70 pF/m
                                                                            0,34 mm2 < 75 pF/m
Operating voltage                               UB               300 V
Test voltage                                       UT               1500 V

Bending radius                                   rmin.           7,5 x cable diameter
Travelling speed                                 vmax.
        freely moving                                                6 m/s 6 m/s 6 m/s
        sliding                                                         3 m/s 3 m/s 3 m/s
Acceleration                                     amax.          7 m/s2 10 m/s2 15 m/s2
Bending cycles at a travelling distance of 7 m
                                                                          10 mio. 5 mio. 2 mio.

Temperature range
         mobile application                                       - 40 °C up to + 80 °C
         fixed installation                                          - 50 °C up to + 80 °C

Oil resistance                                  HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                       HD 22.10
Ozone resistance                             HD 22.2

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2

 

 

 

 

Last Updated (Wednesday, 23 March 2011 16:04)