PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation polypropylene
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Central filler (where applicable), no straight centre pair allowed
D Cabling pairs cabled in concentric layers
D lateral fillers admitted
E Taping polyester fleece
F Screen tinned copper braid, coverage approx. 85%
G Taping polyester fleece
H Jacket polyurethane, matte finish
H Colour grey RAL 7001

Lif9YC11Y  TP DIN

Lif9YC11Y TP DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance                               R                 0,25 mm2 < 77,5 Ohm/km
                                                                                 0,50 mm2 < 39,0 Ohm/km
                                                                                 0,75 mm2 < 26,0 Ohm/km
                                                                                 1,00 mm2 < 19,5 Ohm/km
Insulation resistance                                RI                > 1 GOhm x km
Operating capacitance                             C                 0,25 mm2 < 70 pF/m
                                                                                 0,50 mm2 < 80 pF/m
                                                                                 0,75 mm2 < 90 pF/m
                                                                                 1,00 mm2 < 90 pF/m
Operating voltage                                    UB               300 V
Test voltage                                            UT               1500 V

Bending radius                                       rmin.             7,5 x cable diameter
Travelling speed                                     vmax.
       freely moving                                                        6 m/s 6 m/s 6 m/s
       sliding                                                                 3 m/s 3 m/s 3 m/s
Acceleration                                         amax.             7 m/s2 10 m/s2 15 m/s2
Bending cycles at a travelling distance of 7 m
                                                                                 10 mio. 5 mio. 2 mio.

Temperature range
        mobile application                                               - 40 °C up to + 80 °C
        fixed installation                                                  - 50 °C up to + 80 °C

Oil resistance                                       HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                            HD 22.10
Ozone resistance                                  HD 22.2

Lif9YC11Y TP DIN - [GCE Cables - Italy]

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2

 

 

 

 

Last Updated (Thursday, 24 March 2011 08:51)