PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation PVC compound type TI2 with enhanced properties
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001

LifY11Y ..Z

LifY11Y ..Z - [GCE Cables - Italy]

Technical Data

Conductor resistance                                R               0,50 mm2 < 39,0   Ohm/km
                                                                                0,75 mm2 < 26,0   Ohm/km
                                                                                1,00 mm2 < 19,5   Ohm/km
                                                                                1,50 mm2 < 13,3   Ohm/km
                                                                                2,50 mm2 <   7,98 Ohm/km
                                                                                4,00 mm2 <   4,95 Ohm/km
                                                                                6,00 mm2 <   3,30 Ohm/km
Insulation resistance                                 RI              > 20 MOhm x km
Operating voltage                                      U0/U          300/500 V
Test voltage                                              UT             2500 V

Bending radius                                          rmin.         7,5 x cable diameter
Travelling speed                                        vmax.
      freely moving                                                       5   m/s    5  m/s     5  m/s
      sliding                                                                2,5 m/s  2,5 m/s   2,5 m/s
Acceleration                                             amax.       2   m/s2   4  m/s2  10 m/s2
Bending cycles at a travelling distance of 7 m
                                                                               7 mio. 5 mio. 1,5 mio.

Temperature range
        mobile application                                             -   5 °C up to + 80 °C
        fixed installation                                                - 40 °C up to + 80 °C

Oil resistance                                           HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                                HD 22.10
Ozone resistance                                      HD 22.2

Flame retardance                                      IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version
    UL/CSA approved 300 V  80 °C
    Lif9Y11Y  UL ..Z
  • grey outer jacket RAL 7040
    in compliance with DESINA®

 

 

 

 

Last Updated (Thursday, 24 March 2011 09:16)