PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation PVC compound type TI2 with enhanced properties
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Inner jacket PVC compound type TM2 with enhanced properties
F Screen tinned copper braid, coverage approx. 85%
G Taping polyester fleece
H Jacket polyurethane, matte finish
H Colour grey RAL 7001

LifYYC11Y ..Z

LifYYC11Y ..Z - [GCE Cables - Italy]

Technical Data

Conductor resistance                             R             0,50 mm2 < 39,0   Ohm/km
                                                                           0,75 mm2 < 26,0   Ohm/km
                                                                           1,00 mm2 < 19,5   Ohm/km
                                                                           1,50 mm2 < 13,3   Ohm/km
                                                                           2,50 mm2 <   7,98 Ohm/km
                                                                           4,00 mm2 <   4,95 Ohm/km
                                                                           6,00 mm2 <   3,30 Ohm/km
Insulation resistance                              RI            > 20 MOhm x km
Operating voltage                                   U0/U        300/500 V
Test voltage                                           UT           2500 V

Bending radius                                       rmin.       7,5 x cable diameter
Travelling speed                                     vmax.
      freely moving                                                  5   m/s     5 m/s   5    m/s
      sliding                                                           2,5 m/s  2,5 m/s   2,5 m/s
Acceleration                                         amax.      2   m/s2    4 m/s2  10 m/s2
Bending cycles at a travelling distance of 7 m
                                                                          7 mio. 5 mio. 1,5 mio.

Temperature range
        mobile application                                        -   5 °C up to + 80 °C
        fixed installation                                           - 40 °C up to + 80 °C

Oil resistance                                       HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                            HD 22.10
Ozone resistance                                  HD 22.2

Flame retardance                                  IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version
    UL/CSA approved 300 V  80 °C
    Lif9YHC11Y  UL ..Z

 

Last Updated (Thursday, 24 March 2011 09:58)