PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation PVC compound type TI2 with enhanced properties
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Inner jacket PVC compound type TM2 with enhanced properties
F Screen tinned copper braid, coverage approx. 85%
G Taping polyester fleece
H Jacket polyurethane, matte finish
H Colour grey RAL 7001

LifYYC11Y  UL ..Z

LifYYC11Y UL ..Z - [GCE Cables - Italy]

Technical Data

Conductor resistance                       R               0,50 mm2 < 39,0   Ohm/km
                                                                       0,75 mm2 < 26,0   Ohm/km
                                                                       1,00 mm2 < 19,5   Ohm/km
                                                                       1,50 mm2 < 13,3   Ohm/km
                                                                       2,50 mm2 <   7,98 Ohm/km
                                                                       4,00 mm2 <   4,95 Ohm/km
                                                                       6,00 mm2 <   3,30 Ohm/km
Insulation resistance                        RI              > 20 MOhm x km
Operating voltage                            UB             600 V
Test voltage                                    UT             3000 V

Bending radius                                rmin.          7,5 x cable diameter
Travelling speed                              vmax.
        freely moving                                            5   m/s      5  m/s     5  m/s
        sliding                                                     2,5 m/s    2,5 m/s   2,5 m/s
Acceleration                                   amax.         2   m/s2    4  m/s2  10 m/s2
Bending cycles at a travelling distance of 7 m
                                                                       7 mio. 5 mio. 1,5 mio.

Temperature range
         mobile application                                     -   5 °C up to + 80 °C
         fixed installation                                        - 40 °C up to + 80 °C

Oil resistance                                HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                     HD 22.10
Ozone resistance                           HD 22.2

Flame retardance                           IEC 60332-1, EN 50265-2-1

 

Options

  • other core configurations and cross
    sections manufactured upon request
  • slimline FRNC version
    UL/CSA approved 300 V  80 °C
    Lif9YHC11Y  UL ..Z
  • black outer jacket
    type designation
    LifYYC11Y  UL ..Z BK

 

 

Last Updated (Thursday, 24 March 2011 11:06)