PUR Trailing Cables

Construction

A Conductor highly flexible bare copper rope as per IEC 60228 class 6
B Insulation medium density polyethylene
B Colour black respectively green/yellow
C Jacket polyurethane, matte finish
C Colour grey RAL 7001

Lif2Y11Y 0,6/1 kV

Lif2Y11Y 0.6/1 kV - [GCE Cables - Italy]

Technical Data

Conductor resistance                             R               10 mm2 < 1,910 Ohm/km
                                                                             16 mm2 < 1,210 Ohm/km
                                                                             25 mm2 < 0,780 Ohm/km
                                                                             35 mm2 < 0,554 Ohm/km
                                                                             50 mm2 < 0,386 Ohm/km
                                                                             70 mm2 < 0,272 Ohm/km
                                                                             95 mm2 < 0,206 Ohm/km
                                                                           120 mm2 < 0,161 Ohm/km
                                                                           150 mm2 < 0,129 Ohm/km
                                                                           185 mm2 < 0,106 Ohm/km
Insulation resistance                              RI             > 1 GOhm x km
Operating voltage                                  U0/U         0,6/1 kV
Test voltage                                          UT            4000 V

Bending radius                                     rmin.         7,5 x cable diameter
Travelling speed                                   vmax.
       freely moving                                                 10 m/s  10 m/s  10 m/s
       sliding                                                            5 m/s    5 m/s    5 m/s
Acceleration                                        amax.         7 m/s2 10 m/s2 30 m/s2
Bending cycles at a travelling distance of 7 m
                                                                           15 mio. 7 mio. 2 mio.

Temperature range
        mobile application                                         - 40 °C up to + 80 °C
        fixed installation                                            - 50 °C up to + 80 °C

Oil resistance                                     HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                          HD 22.10
Ozone resistance                                HD 22.2

 

Lif2Y11Y 0.6/1kV G/V -[GCE Cables - Italy]

Options

  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2

 

 

 

Last Updated (Friday, 25 March 2011 08:26)