PUR Trailing Cables

Construction

A Conductor highly flexible bare copper rope as per IEC 60228 class 6
B Insulation medium density polyethylene
B Colour black respectively green/yellow
C Screen tinned copper braid, coverage approx. 85%
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001

Lif2YC11Y  0,6/1 kV

Lif2YC11Y 0.6/1 kV - [GCE Cables -Italy]

Technical Data

Conductor resistance                              R                   10 mm2 < 1,910 Ohm/km
                                                                                  16 mm2 < 1,210 Ohm/km
                                                                                  25 mm2 < 0,780 Ohm/km
                                                                                  35 mm2 < 0,554 Ohm/km
                                                                                  50 mm2 < 0,386 Ohm/km
                                                                                  70 mm2 < 0,272 Ohm/km
                                                                                  95 mm2 < 0,206 Ohm/km
                                                                                120 mm2 < 0,161 Ohm/km
                                                                                150 mm2 < 0,129 Ohm/km
                                                                                185 mm2 < 0,106 Ohm/km
Insulation resistance                               RI                 > 1 GOhm x km
Operating voltage                                   U0/U             0,6/1 kV
Test voltage                                           UT                4000 V

Bending radius                                      rmin.             7,5 x cable diameter
Travelling speed                                    vmax.
       freely moving                                                      10 m/s  10 m/s   10 m/s
       sliding                                                                 5 m/s    5 m/s     5 m/s
Acceleration                                         amax.             7 m/s2 10 m/s2 30 m/s2
Bending cycles at a travelling distance of 7 m
                                                                                 15 mio. 7 mio. 2 mio.

Temperature range
        mobile application                                               - 40 °C up to + 80 °C
        fixed installation                                                  - 50 °C up to + 80 °C

Oil resistance                                      HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                           HD 22.10
Ozone resistance                                 HD 22.2

 

Lif2YC11Y 0.6/1 kV G/V- [GCE Cables -Italy]

Options

  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2

 

 

 