Lif2YC11Y 0,6/1 kV
PUR Trailing Cables
Construction
A Conductor highly flexible bare copper rope as per IEC 60228 class 6
B Insulation medium density polyethylene
B Colour black respectively green/yellow
C Screen tinned copper braid, coverage approx. 85%
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001
Lif2YC11Y 0,6/1 kV
![Lif2YC11Y 0.6/1 kV - [GCE Cables -Italy]](/images/stories/cables/Trailing_Cables_for_Cable_Chains/Lif2YC11Y_0.6-1kV.jpg)
Technical Data
Conductor resistance R 10 mm2 < 1,910 Ohm/km
16 mm2 < 1,210 Ohm/km
25 mm2 < 0,780 Ohm/km
35 mm2 < 0,554 Ohm/km
50 mm2 < 0,386 Ohm/km
70 mm2 < 0,272 Ohm/km
95 mm2 < 0,206 Ohm/km
120 mm2 < 0,161 Ohm/km
150 mm2 < 0,129 Ohm/km
185 mm2 < 0,106 Ohm/km
Insulation resistance RI > 1 GOhm x km
Operating voltage U0/U 0,6/1 kV
Test voltage UT 4000 V
Bending radius rmin. 7,5 x cable diameter
Travelling speed vmax.
freely moving 10 m/s 10 m/s 10 m/s
sliding 5 m/s 5 m/s 5 m/s
Acceleration amax. 7 m/s2 10 m/s2 30 m/s2
Bending cycles at a travelling distance of 7 m
15 mio. 7 mio. 2 mio.
Temperature range
mobile application - 40 °C up to + 80 °C
fixed installation - 50 °C up to + 80 °C
Oil resistance HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance HD 22.10
Ozone resistance HD 22.2
![Lif2YC11Y 0.6/1 kV G/V- [GCE Cables -Italy]](/images/stories/cables/Trailing_Cables_for_Cable_Chains/Lif2YC11Y_0.6-1kV_G-V.jpg)
Options
- FRNC version
flame retardant as per IEC 60332-1
non corrosive as per IEC 60754-1 & -2
Last Updated (Friday, 25 March 2011 08:41)