PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation modified polyester (TPE-E)
B dentification colour code as per DIN 47100
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Screen tinned copper braid, coverage approx. 85%
F Taping polyester fleece
G Jacket polyurethane, matte finish
G Colour grey RAL 7001

Lif12YC11Y DIN

Lif12YC11Y DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance                               R                 0,14 mm2 < 138,0 Ohm/km
                                                                                 0,25 mm2 <   77,5 Ohm/km
                                                                                 0,34 mm2 <   56,0 Ohm/km
Insulation resistance                                RI                > 100 MOhm x km
Operating capacitance                             C                 0,14 mm2 <   90 pF/m
                                                                                 0,25 mm2 < 100 pF/m
                                                                                 0,34 mm2 < 110 pF/m
Operating voltage                                    UB                300 V
Test voltage                                            UT                1500 V

Bending radius                                       rmin.             7,5 x cable diameter
Travelling speed                                     vmax.
       freely moving                                                       10 m/s  10 m/s   10 m/s
       sliding                                                                  5 m/s    5 m/s     5 m/s
Acceleration                                          amax.             7 m/s2 10 m/s2 15 m/s2
Bending cycles at a travelling distance of 7 m
                                                                                  7 mio. 3 mio. 1 mio.

Temperature range
        mobile application                                                - 40 °C up to + 80 °C
        fixed installation                                                   - 50 °C up to + 80 °C

Oil resistance                                         HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                              HD 22.10
Ozone resistance                                    HD 22.2

 

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2

 

 

Last Updated (Friday, 25 March 2011 09:10)