PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation modified polyester (TPE-E)
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Central filler (where applicable), no straight centre pair allowed
D Cabling pairs cabled in concentric layers
D lateral fillers admitted
E Taping polyester fleece
F Screen tinned copper braid, coverage approx. 85%
G Taping polyester fleece
H Jacket polyurethane, matte finish
H Colour grey RAL 7001

Lif12YC11Y TP DIN

Lif12YC11Y TP DIN - [GCE Cables - Italy]

Technical Data

Conductor resistance                            R                0,25 mm2 < 77,5 Ohm/km
                                                                             0,50 mm2 < 39,0 Ohm/km
                                                                             0,75 mm2 < 26,0 Ohm/km
                                                                             1,00 mm2 < 19,5 Ohm/km
Insulation resistance                             RI                > 100 MOhm x km
Operating capacitance                          C                0,25 mm2 < 100 pF/m
                                                                             0,50 mm2 < 120 pF/m
                                                                             0,75 mm2 < 120 pF/m
                                                                             1,00 mm2 < 120 pF/m
Operating voltage                                 UB              300 V
Test voltage                                         UT              1500 V

Bending radius                                     rmin.           7,5 x cable diameter
Travelling speed                                   vmax.
       freely moving                                                   10 m/s  10 m/s   10 m/s
       sliding                                                              5 m/s    5 m/s     5 m/s
Acceleration                                        amax.           7 m/s2 10 m/s2 15 m/s2
Bending cycles at a travelling distance of 7 m
                                                                             10 mio. 5 mio. 2 mio.

Temperature range
         mobile application                                          - 40 °C up to + 80 °C
         fixed installation                                             - 50 °C up to + 80 °C

Oil resistance                                     HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                          HD 22.10
Ozone resistance                                HD 22.2

 

Lif12YC11Y TP DIN DESINA - [GCE Cables - Italy]

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2

 

 

 