PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation modified polyester (TPE-E)
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001

Lif12Y11Y ..Z

Lif12Y11Y ..Z - [GCE Cables - Italy]

Technical Data

Conductor resistance                              R                0,50 mm2 < 39,0   Ohm/km
                                                                               0,75 mm2 < 26,0   Ohm/km
                                                                               1,00 mm2 < 19,5   Ohm/km
                                                                               1,50 mm2 < 13,3   Ohm/km
                                                                                2,50 mm2 <   7,98 Ohm/km
Insulation resistance                               RI                > 100 MOhm x km
Operating voltage                                   U0/U            300/500 V
Test voltage                                           UT               2500 V

Bending radius                                       rmin.           5 x cable diameter
Travelling speed                                     vmax.
        freely moving                                                    10 m/s   10 m/s   10 m/s
        sliding                                                               5 m/s     5 m/s    5 m/s
Acceleration                                          amax.           7 m/s2 10 m/s2 25 m/s2
Bending cycles at a travelling distance of 7 m
                                                                               10 mio. 5 mio. 2 mio.

Temperature range
        mobile application                                             - 40 °C up to + 80 °C
        fixed installation                                                - 50 °C up to + 80 °C

Oil resistance                                       HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                            HD 22.10
Ozone resistance                                  HD 22.2

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2
  • grey outer jacket RAL 7040
    in compliance with DESINA®

 

 

 

Last Updated (Friday, 25 March 2011 10:20)