PUR Trailing Cables

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation modified polyester (TPE-E)
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001

Lif12Y11Y  UL ..Z

Lif12Y11Y UL ..Z - [GCE Cables - Italy]

Technical Data

Conductor resistance                           R               0,50 mm2 < 39,0   Ohm/km
                                                                           0,75 mm2 < 26,0   Ohm/km
                                                                           1,00 mm2 < 19,5   Ohm/km
                                                                           1,50 mm2 < 13,3   Ohm/km
                                                                           2,50 mm2 <   7,98 Ohm/km
                                                                           4,00 mm2 <   4,95 Ohm/km
                                                                           6,00 mm2 <   3,30 Ohm/km
Insulation resistance                            RI              > 100 MOhm x km
Operating voltage                                UB             600 V
Test voltage                                        UT             3000 V

Bending radius                                   rmin.           5 x cable diameter
Travelling speed                                 vmax.
       freely moving                                                10 m/s   10 m/s   10 m/s
       sliding                                                            5 m/s    5 m/s     5 m/s
Acceleration                                      amax.           7 m/s2 10 m/s2 25 m/s2
Bending cycles at a travelling distance of 7 m
                                                                           10 mio. 5 mio. 2 mio.

Temperature range
       mobile application                                          - 40 °C up to + 80 °C
       fixed installation                                             - 50 °C up to + 80 °C

Oil resistance                                    HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                         HD 22.10
Ozone resistance                               HD 22.2

Flame retardance                               IEC 60332-1, EN 50265-2-1
Halogen content                                 IEC 60754-1
Corrosivity                                         IEC 60754-2
Smoke density                                  IEC 61034, EN 50268-2 LT > 60%

Options

  • other core configurations and cross
    sections manufactured upon request
  • slimline version 300 V  80 °C
    UL/CSA approved
  • grey outer jacket RAL 7040
    in compliance with DESINA®

 

Last Updated (Friday, 25 March 2011 11:53)