Lif12Y11Y UL ..Z
PUR Trailing Cables
Construction
A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation modified polyester (TPE-E)
B Identification black number coded, green/yellow in the outer layer (JZ)
C Central filler (where applicable), no straight centre conductor allowed
C Cabling conductors cabled in concentric layers
C lateral fillers admitted
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001
Lif12Y11Y UL ..Z
![Lif12Y11Y UL ..Z - [GCE Cables - Italy]](/images/stories/cables/Trailing_Cables_for_Cable_Chains/Lif12Y11Y_UL..Z.jpg)
Technical Data
Conductor resistance R 0,50 mm2 < 39,0 Ohm/km
0,75 mm2 < 26,0 Ohm/km
1,00 mm2 < 19,5 Ohm/km
1,50 mm2 < 13,3 Ohm/km
2,50 mm2 < 7,98 Ohm/km
4,00 mm2 < 4,95 Ohm/km
6,00 mm2 < 3,30 Ohm/km
Insulation resistance RI > 100 MOhm x km
Operating voltage UB 600 V
Test voltage UT 3000 V
Bending radius rmin. 5 x cable diameter
Travelling speed vmax.
freely moving 10 m/s 10 m/s 10 m/s
sliding 5 m/s 5 m/s 5 m/s
Acceleration amax. 7 m/s2 10 m/s2 25 m/s2
Bending cycles at a travelling distance of 7 m
10 mio. 5 mio. 2 mio.
Temperature range
mobile application - 40 °C up to + 80 °C
fixed installation - 50 °C up to + 80 °C
Oil resistance HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance HD 22.10
Ozone resistance HD 22.2
Flame retardance IEC 60332-1, EN 50265-2-1
Halogen content IEC 60754-1
Corrosivity IEC 60754-2
Smoke density IEC 61034, EN 50268-2 LT > 60%
Options
- other core configurations and cross
sections manufactured upon request - slimline version 300 V 80 °C
UL/CSA approved - grey outer jacket RAL 7040
in compliance with DESINA®

Last Updated (Friday, 25 March 2011 11:53)