PUR Trailing Cables

Construction

A Conductor highly flexible bare copper rope as per IEC 60228 class 6
B Insulation modified polyester (TPE-E)
B Colour black respectively green/yellow
C Screen tinned copper braid, coverage approx. 85%
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour grey RAL 7001

Lif12YC11Y  0,6/1 kV

Lif12YC11Y 0.6/1 kV - [GCE Cables - Italy]

Technical Data

Conductor resistance                            R              10 mm2 < 1,910 Ohm/km
                                                                           16 mm2 < 1,210 Ohm/km
                                                                           25 mm2 < 0,780 Ohm/km
                                                                           35 mm2 < 0,554 Ohm/km
                                                                           50 mm2 < 0,386 Ohm/km
                                                                           70 mm2 < 0,272 Ohm/km
                                                                           95 mm2 < 0,206 Ohm/km
                                                                         120 mm2 < 0,161 Ohm/km
                                                                         150 mm2 < 0,129 Ohm/km
                                                                         185 mm2 < 0,106 Ohm/km
Insulation resistance                             RI            > 100 MOhm x km
Operating voltage                                 U0/U        0,6/1 kV
Test voltage                                         UT           4000 V

Bending radius                                    rmin.        7,5 x cable diameter
Travelling speed                                  vmax.
      freely moving                                                 10 m/s  10 m/s   10 m/s
      sliding                                                            5 m/s    5 m/s     5 m/s
Acceleration                                       amax.         7 m/s2 10 m/s2 50 m/s2
Bending cycles at a travelling distance of 7 m
                                                                           15 mio. 7 mio. 1 mio.

Temperature range
        mobile application                                        - 40 °C up to + 80 °C
        fixed installation                                           - 50 °C up to + 80 °C

Oil resistance                                    HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                         HD 22.10
Ozone resistance                               HD 22.2

 

Lif12YC11Y 0.6/1 kV G/V - [GCE Cables - Italy]

Options

  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2