PUR Trailing Cables
for resolver systems

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
A 0,25 mm2 32 x 0,10 mm
B Insulation modified polyester (TPE-E)
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Taping polyester foil
D Pair screen tinned copper spiral, coverage approx. 95%
E Pair jacket modified polyester (TPE-E)
F Central filler (where applicable) flexible synthetic rope as strain relief
F Cabling pairs cabled in a concentric layer
F lateral fillers admitted
G Taping polyester fleece
H Screen tinned copper braid, coverage approx. 85%
I Taping polyester fleece
J Jacket polyurethane, matte finish
J Colour green RAL 6018

Lif12YC11Y RE

Lif12YC11Y RE - [GCE Cables - Italy]

Lif12YC11Y RE - [GCE Cables - Italy]

Technical Data

Conductor resistance                    R              < 77,5 Ohm/km
Insulation resistance                     RI             > 100 MOhm x km
Operating capacitance                  C              < 120 pF/m
Operating voltage                         UB            300 V
Test voltage                                 UT            1500 V
Bending radius                             rmin.         12 x cable diameter
Travelling speed                           vmax.
      freely moving                                          10 m/s 10 m/s 10 m/s
      sliding                                                     5 m/s 5 m/s 5 m/s
Acceleration                                amax.         7 m/s2 10 m/s2 15 m/s2
Bending cycles at a travelling distance of 7 m
                                                                   10 mio. 5 mio. 2 mio.

Temperature range
        mobile application                - 40 °C up to + 80 °C
        fixed installation                   - 50 °C up to + 80 °C

Oil resistance                              HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                   HD 22.10
Ozone resistance                         HD 22.2

Options

  • tinned copper drain wire
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2
  • low capacitance versions
  • PVC installation cables