Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
A 0,25 mm2 32 x 0,10 mm
B Insulation polypropylene
B Identification colour code as per DIN 47100
C Cabling conductors twisted to pairs
D Taping polyester foil
D Pair screen tinned copper spiral, coverage approx. 95%
E Pair jacket polyurethane
F Central filler (where applicable) flexible synthetic rope as strain relief
F Cabling pairs cabled in a concentric layer
F lateral fillers admitted
G Taping polyester fleece
H Screen tinned copper braid, coverage approx. 85%
I Taping polyester fleece
J Jacket polyurethane, matte finish
J Colour green RAL 6018

Lif9YC11Y RE

Lif9YC11Y RE - [GCE Cables - Italy]

Lif9YC11Y RE - [GCE Cables -Italy]

Technical Data

Conductor resistance                            R                 < 77,5 Ohm/km
Insulation resistance                             RI                > 1 GOhm x km
Operating capacitance                          C                 < 90 pF/m
Operating voltage                                 UB               300 V
Test voltage                                         UT               1500 V

Bending radius                                     rmin.            12 x cable diameter
Travelling speed                                   vmax.
        freely moving                                                    6 m/s 6 m/s 6 m/s
        sliding                                                             3 m/s 3 m/s 3 m/s
Acceleration                                        amax.           7 m/s2 10 m/s2 15 m/s2
Bending cycles at a travelling distance of 7 m
                                                                             10 mio. 5 mio. 2 mio.

Temperature range
        mobile application                        - 40 °C up to + 80 °C
        fixed installation                           - 50 °C up to + 80 °C

Oil resistance                                      HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                           HD 22.10
Ozone resistance                                 HD 22.2

Options

  • tinned copper drain wire
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2
  • TPE-E/PUR versions
  • PVC installation cables