Sensor Actuator Cables
for M12 connectors

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
A 0,25 mm2 32 x 0,10 mm
A 0,34 mm2 42 x 0,10 mm
B Insulation PVC compound type TI2 with enhanced properties
B Identification special colour code, refer to the CAD drawing for our standard
C Central filler (where applicable) flexible synthetic rope
C Cabling conductors cabled in a concentric layer
D Separator non hygroscopic talcum powder
E Jacket PVC compound type TM2 with enhanced properties
E respectively polyurethane, matte finish
E Colour yellow RAL 1021

Note
Only cables 4 x 0,34 mm2 are in compliance with DESINA®. The other cables listed
on this page must not carry the DESINA® marking on the jacket.

LifYY SAL

LifYY SAL - [GCE Cables - Italy]

Technical Data

Conductor resistance                         R               0,25 mm2 < 77,5 Ohm/km
                                                                         0,34 mm2 < 56,0 Ohm/km
Insulation resistance                          RI              > 20 MOhm x km
Operating capacitance                       C               0,25 mm2 < 100 pF/m
                                                                         0,34 mm2 < 110 pF/m
Operating voltage                              UB             300 V
Test voltage                                      UT             1500 V

type LifYY  SAL                 (with PVC jacket)

Bending radius                                  rmin.          7,5 x cable diameter
      freely moving                                                4 m/s 4 m/s
      sliding                                                         2 m/s 2 m/s
Acceleration                                     amax.        2 m/s2 4 m/s2
Bending cycles at a travelling distance of 5 m
                                                                        3 mio. 2 mio.

Temperature range
         mobile application                    -   5 °C up to + 80 °C
         fixed installation                       - 40 °C up to + 80 °C

Oil resistance                                  IEC 60811-2-1

Flame retardance                             IEC 60332-1, EN 50265-2-1

Options

  • FRNC version
    type designation
    LifHH  SAL