LifYY SAL
Sensor Actuator Cables
for M12 connectors
Construction
A Conductor highly flexible bare copper as per IEC 60228 class 6
A 0,25 mm2 32 x 0,10 mm
A 0,34 mm2 42 x 0,10 mm
B Insulation PVC compound type TI2 with enhanced properties
B Identification special colour code, refer to the CAD drawing for our standard
C Central filler (where applicable) flexible synthetic rope
C Cabling conductors cabled in a concentric layer
D Separator non hygroscopic talcum powder
E Jacket PVC compound type TM2 with enhanced properties
E respectively polyurethane, matte finish
E Colour yellow RAL 1021
Note
Only cables 4 x 0,34 mm2 are in compliance with DESINA®. The other cables listed
on this page must not carry the DESINA® marking on the jacket.
LifYY SAL
![LifYY SAL - [GCE Cables - Italy]](/images/stories/cables/Special_Cables_for_Factory_Automation/LifYY_SAL.jpg)
Technical Data
Conductor resistance R 0,25 mm2 < 77,5 Ohm/km
0,34 mm2 < 56,0 Ohm/km
Insulation resistance RI > 20 MOhm x km
Operating capacitance C 0,25 mm2 < 100 pF/m
0,34 mm2 < 110 pF/m
Operating voltage UB 300 V
Test voltage UT 1500 V
type LifYY SAL (with PVC jacket)
Bending radius rmin. 7,5 x cable diameter
freely moving 4 m/s 4 m/s
sliding 2 m/s 2 m/s
Acceleration amax. 2 m/s2 4 m/s2
Bending cycles at a travelling distance of 5 m
3 mio. 2 mio.
Temperature range
mobile application - 5 °C up to + 80 °C
fixed installation - 40 °C up to + 80 °C
Oil resistance IEC 60811-2-1
Flame retardance IEC 60332-1, EN 50265-2-1
Options
- FRNC version
type designation
LifHH SAL