Valve Plug Cables
for M12 connectors

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
A 0,50 mm2 28 x 0,15 mm
A 0,75 mm2 42 x 0,15 mm
B Insulation PVC compound type TI2 with enhanced properties
B Identification special colour code, refer to the CAD drawing for our standard
C Central filler (where applicable) flexible synthetic rope
C Cabling conductors cabled in a concentric layer
D Separator non hygroscopic talcum powder
E Jacket PVC compound type TM2 with enhanced properties
E Colour black RAL 9005

LifYY VP

LifYY VP - [GCE Cables - Italy]

Technical Data

Conductor resistance                       R                  0,50 mm2 < 39,0 Ohm/km
                                                                          0,75 mm2 < 26,0 Ohm/km
Insulation resistance                        RI                 > 20 MOhm x km
Operating voltage                            U0/U             300/300 V
Test voltage                                    UT                2000 V

Bending radius                               rmin.             7,5 x cable diameter
      freely moving                                                4 m/s 4 m/s
      sliding                                                         2 m/s 2 m/s
Acceleration                                  amax.           2 m/s2 4 m/s2
Bending cycles at a travelling distance of 5 m
                                                                        3 mio. 2 mio.

Temperature range
         mobile application                 -   5 °C up to + 80 °C
         fixed installation                    - 40 °C up to + 80 °C

Oil resistance                               IEC 60811-2-1
Flame retardance                          IEC 60332-1, EN 50265-2-1

Options

  • alternative colour codes in use
  • FRNC version
    flame retardant as per IEC 60332-1
    non corrosive as per IEC 60754-1 & -2
  • PUR trailing cables
    type designation
    LifY11Y  VP