PUR Trailing Cables
for M12 actuator sensor boxes

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
A 0,25 mm2 32 x 0,10 mm
A 0,34 mm2 42 x 0,10 mm
A 0,50 mm2 64 x 0,10 mm
A 0,75 mm2 96 x 0,10 mm
A 1,00 mm2 128 x 0,10 mm
B Insulation PVC compound type TI2 with enhanced properties
B Identification special colour code, refer to the CAD drawing for our standard
C Central filler (where applicable) flexible synthetic rope as strain relief
C or extruded dummy element
C Cabling conductors cabled in concentric layers
D Taping polyester fleece
E Jacket polyurethane, matte finish
E Colour black RAL 9005

LifY11Y ASI

LifY11Y ASI - [GCE Cables - Italy]

LifY11Y ASI - [GCE Cables - Italy]

LifY11Y ASI - [GCE Cables - Italy]

Technical Data

Conductor resistance                                R                 0,25 mm2 < 77,5 Ohm/km
                                                                                  0,34 mm2 < 56,0 Ohm/km
                                                                                  0,50 mm2 < 39,0 Ohm/km
                                                                                  0,75 mm2 < 26,0 Ohm/km
                                                                                  1,00 mm2 20 MOhm x km
Operating voltage                                     UB               300 V
Test voltage                                             UT               1500 V

Bending radius                                        rmin.            10 x cable diameter
        freely moving                                                      4 m/s 4 m/s 4 m/s
        sliding                                                               2 m/s 2 m/s 2 m/s
Acceleration                                           amax.          2 m/s2 5 m/s2 10 m/s2
Bending cycles at a travelling distance of 5 m
                                                                               10 mio. 5 mio. 2 mio.

Temperature range
       mobile application                         -   5 °C up to + 80 °C
       fixed installation                            - 40 °C up to + 80 °C

Oil resistance                                     HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                          HD 22.10
Ozone resistance                                HD 22.2

Options

  • other core configurations and cross
    sections manufactured upon request
  • flame retardant version