PVC Servo Cables

Construction

A Conductor flexible bare copper as per IEC 60228 class 5
B Insulation medium density polyethylene
B Identification black number coded, green/yellow
C Central filler extruded dummy element
C Cabling conductors cabled in a concentric layer
C lateral fillers admitted
D Taping polyester foil
E Screen tinned copper braid, coverage approx. 85%
F Jacket special PVC compound type as per class 43
F Colour orange RAL 2003

2YSLCY-JZ  UL

2YSLCY-JZ UL - [GCE Cables -Italy]

Technical Data

Conductor resistance                         R               1,50 mm2 < 13,30   Ohm/km
                                                                         2,50 mm2 <   7,98   Ohm/km
                                                                         4,00 mm2 <   4,95   Ohm/km
                                                                         6,00 mm2 <   3,30   Ohm/km
                                                                       10,00 mm2 <   1,91   Ohm/km
                                                                       16,00 mm2 <   1,21   Ohm/km
                                                                       25,00 mm2 <   0,780 Ohm/km
                                                                       35,00 mm2 <   0,554 Ohm/km
                                                                       50,00 mm2 <   0,386 Ohm/km
Insulation resistance                         RI             > 1 GOhm x km
Operating capacitance                      C              < 200 pF/m
Transfer impedance                          ZT             < 250 mOhm/m
Nominal voltage                               U0/U          0,6/1 kV        as per VDE
                                                      U              1000 V          as per UL
Operating voltage                             UB0/UB     0,7/1,2 kV AC
                                                                       0,9/1,8 kV DC
Peak voltage                                   Û               1,7 kV
Test voltage                                    UT              4 kV

Bending radius                               rmin.
       mobile application                                    15 x cable diameter
       fixed installation                                        8 x cable diameter

Max. admissible conductor temperature
       continuous                                       +   90 °C
       in case of short circuit                       + 250 °C

Temperature range
       mobile application                             -   5 °C up to + 80 °C
       fixed installation                                - 40 °C up to + 80 °C

Oil resistance                                         IEC 60811-2-1

Flame retardance                                   IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • polyester coated aluminium foil
    in contact with the braid screen
  • PUR trailing cables
  • PUR versions

 

 

 

 

Last Updated (Friday, 17 June 2011 11:15)