PVC Servo Cables

Construction

A Conductor flexible bare copper as per IEC 60228 class 5
B Insulation PVC compound TI2 with enhanced properties
B Identification black number coded, green/yellow
C Central filler extruded dummy element
C Cabling conductors cabled in a concentric layer
D Separator non hygroscopic talcum powder
E Inner jacket PVC compound TM2 with enhanced properties
F Screen tinned copper braid, coverage approx. 85%
G Jacket PVC compound TM2 with enhanced properties
G Colour orange RAL 2003

YSLYCY-JZ

YSLYCY-JZ - [GCE Cables -Italy]

Technical Data

Conductor resistance                                R             1,50 mm2 < 13,30   Ohm/km
                                                                              2,50 mm2 <   7,98   Ohm/km
                                                                              4,00 mm2 <   4,95   Ohm/km
                                                                              6,00 mm2 <   3,30   Ohm/km
                                                                            10,00 mm2 <   1,91   Ohm/km
                                                                            16,00 mm2 <   1,21   Ohm/km
                                                                            25,00 mm2 <   0,780 Ohm/km
                                                                            35,00 mm2 <   0,554 Ohm/km
                                                                            50,00 mm2 <   0,386 Ohm/km
Insulation resistance                                 RI          > 20 MOhm x km
Transfer impedance                                  ZT          < 250 mOhm/m
Nominal voltage                                       U0/U       0,6/1 kV
Operating voltage                                    UB0/UB   0,7/1,2 kV AC
                                                                            0,9/1,8 kV DC
Peak voltage                                           Û            1,7 kV
Test voltage                                            UT          4 kV

Bending radius                                       rmin.
       mobile application                                           15 x cable diameter
       fixed installation                                               8 x cable diameter

Max. admissible conductor temperature
       continuous                                    +   80 °C
       in case of short circuit                    + 160 °C

Temperature range
       mobile application                          -   5 °C up to + 80 °C
       fixed installation                             - 40 °C up to + 80 °C

Oil resistance                                      IEC 60811-2-1

Flame retardance                                 IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version HSLHCH-JZ  0,6/1 kV
    fire retardant as per IEC 60332-3C
    non corrosive as per IEC 60754-1 & -2