PUR Servo Cables
for trailing chains

Construction

A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation medium density polyethylene
B Identification black with printing U / L1 / C / L+, V / L2 resp. W / L3 / D / L-,
B green/yellow
C Central filler flexible synthetic rope as strain relief
C Cabling conductors cabled in a concentric layer
D Lateral filler flexible synthetic rope
E Taping polyester fleece
F Screen tinned copper braid, coverage approx. 85%
G Taping polyester fleece
H Jacket polyurethane, matte finish
H Colour orange RAL 2003

Lif2YC11Y-JZ

Lif2YC11Y-JZ - [GCE Cables - Italy]

Technical Data

Conductor resistance                              R                 1,50 mm2 < 13,30 Ohm/km
                                                                                2,50 mm2 <   7,98 Ohm/km
                                                                                4,00 mm2 <   4,95 Ohm/km
                                                                                6,00 mm2 <   3,30 Ohm/km
                                                                              10,00 mm2 <   1,91 Ohm/km
Insulation resistance                               RI                > 1 GOhm x km
Operating capacitance                            C                 < 120 pF/m
Transfer impedance                                ZT                < 250 mOhm/m
Nominal voltage                                     U0/U             0,6/1 kV
Operating voltage                                   UB0/UB        0,7/1,2 kV AC
                                                                                0,9/1,8 kV DC
Peak voltage                                         Û                  1,7 kV
Test voltage                                          UT                 4 kV

Bending radius                                     rmin.              12 x cable diameter
Travelling speed                                   vmax.
       freely moving                                                      6 m/s 6 m/s 6 m/s
       sliding                                                               3 m/s 3 m/s 3 m/s
Acceleration                                       amax.             2 m/s2 4 m/s2 10 m/s2
Bending cycles at a travelling distance of 7 m
                                                                             10 mio. 5 mio. 2 mio.

Max. admissible conductor temperature
        continuous                                +   90 °C
        in case of short circuit                + 250 °C

Temperature range
        mobile application                      - 20 °C up to + 80 °C
        fixed installation                         - 50 °C up to + 80 °C

Oil resistance                                    HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance                         HD 22.10
Ozone resistance                               HD 22.2

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version as per IEC 60332-1,
    IEC 60754-1 & -2
  • PUR trailing cables
  • PUR installation cables
  • PVC installation cables