Lif2YC11Y-JZ
PUR Servo Cables
for trailing chains
Construction
A Conductor highly flexible bare copper as per IEC 60228 class 6
B Insulation medium density polyethylene
B Identification black with printing U / L1 / C / L+, V / L2 resp. W / L3 / D / L-,
B green/yellow
C Central filler flexible synthetic rope as strain relief
C Cabling conductors cabled in a concentric layer
D Lateral filler flexible synthetic rope
E Taping polyester fleece
F Screen tinned copper braid, coverage approx. 85%
G Taping polyester fleece
H Jacket polyurethane, matte finish
H Colour orange RAL 2003
Lif2YC11Y-JZ
![Lif2YC11Y-JZ - [GCE Cables - Italy]](/images/stories/cables/Special_Cables_for_Factory_Automation/Lif2YC11Y_JZ.jpg)
Technical Data
Conductor resistance R 1,50 mm2 < 13,30 Ohm/km
2,50 mm2 < 7,98 Ohm/km
4,00 mm2 < 4,95 Ohm/km
6,00 mm2 < 3,30 Ohm/km
10,00 mm2 < 1,91 Ohm/km
Insulation resistance RI > 1 GOhm x km
Operating capacitance C < 120 pF/m
Transfer impedance ZT < 250 mOhm/m
Nominal voltage U0/U 0,6/1 kV
Operating voltage UB0/UB 0,7/1,2 kV AC
0,9/1,8 kV DC
Peak voltage Û 1,7 kV
Test voltage UT 4 kV
Bending radius rmin. 12 x cable diameter
Travelling speed vmax.
freely moving 6 m/s 6 m/s 6 m/s
sliding 3 m/s 3 m/s 3 m/s
Acceleration amax. 2 m/s2 4 m/s2 10 m/s2
Bending cycles at a travelling distance of 7 m
10 mio. 5 mio. 2 mio.
Max. admissible conductor temperature
continuous + 90 °C
in case of short circuit + 250 °C
Temperature range
mobile application - 20 °C up to + 80 °C
fixed installation - 50 °C up to + 80 °C
Oil resistance HD 505.2.1, VDE 0472 part 803 class A/B
Hydrolysis resistance HD 22.10
Ozone resistance HD 22.2
Options
- other core configurations and cross
sections manufactured upon request - FRNC version as per IEC 60332-1,
IEC 60754-1 & -2 - PUR trailing cables
- PUR installation cables
- PVC installation cables