PVC Servo Cables

Construction

A Conductor flexible bare copper as per DIN 0812 resp. IEC 60228 class 5
B Insulation PVC compound type TI2 with enhanced properties
B Identification power conductors black with printing U / L1 / C / L+, V / L2 resp.
B W / L3 / D / L-, green/yellow
B control conductors black number coded 5 - 8 for two pair con-
B struction (except control pairs 0,34 mm2 - colour coded as per CAD
B drawing), with printing BR1 resp. BR2 for one pair construction
C Screen polyester coated aluminium foil
D Drain wire tinned stranded copper
E Screen tinned copper braid, coverage approx. 85%
F Taping polyester foil
G Central filler flexible synthetic rope
G Cabling power conductors and pair(s) cabled in a concentric layer
G lateral fillers admitted
H Taping polyester foil
I Screen tinned copper braid, coverage approx. 85%
J Jacket PVC compound type TM2 with enhanced properties
J Colour orange RAL 2003

YSLCY

YSLCY - [GCE Cables -Italy]

YSLCY - [GCE Cables -Italy]

Technical Data

Conductor resistance                                  R              0,34 mm2 < 56,0   Ohm/km
                                                                                 0,75 mm2 < 26,0   Ohm/km
                                                                                 1,00 mm2 < 19,5   Ohm/km
                                                                                 1,50 mm2 < 13,3   Ohm/km
                                                                                 2,50 mm2 <   7,98 Ohm/km
                                                                                 4,00 mm2 <   4,95 Ohm/km
                                                                                 6,00 mm2 <   3,30 Ohm/km
                                                                               10,00 mm2 <   1,91 Ohm/km
Insulation resistance                                  RI              > 20 MOhm x km
Transfer impedance                                   ZT              < 250 mOhm/m
Operating voltage                                      U0/U         0,6/1 kV (power conductors)
                                                               UB            300 V (control conductors)
Test voltage                                              UT            4 kV (power conductors)
                                                                               1,5 kV (control conductors)

Bending radius                                         rmin.         10 x cable diameter

Temperature range
       mobile application                     -   5 °C up to + 80 °C
       fixed installation                       - 40 °C up to + 80 °C

Oil resistance                                 IEC 60811-2-1

Flame retardance                            IEC 60332-1, EN 50265-2-1

Options

  • other core configurations and cross
    sections manufactured upon request
  • FRNC version HSLCH SERVO
    fire retardant as per IEC 60332-3C
    non corrosive as per IEC 60754-1 & -2
  • PUR trailing cables
  • PUR trailing cables
    low capacitance versions