YSLCY UL
PVC Servo Cables
Construction
A Conductor flexible bare copper as per IEC 60228 class 5
B Insulation PVC compound type TI2 with enhanced properties
B Identification power conductors black with printing U / L1 / C / L+, V / L2 resp.
B W / L3 / D / L-, green/yellow
B control conductors black number coded 5 - 8 for two pair con-
B struction, with printing BR1 resp. BR2 for one pair construction
C Screen polyester coated aluminium foil
D Drain wire tinned stranded copper
E Screen tinned copper braid, coverage approx. 85%
F Taping polyester foil
G Central filler flexible synthetic rope
G Cabling power conductors and pair(s) cabled in a concentric layer
G lateral fillers admitted
H Taping polyester foil
I Screen tinned copper braid, coverage approx. 85%
J Jacket special PVC compound type as per class 43
J Colour orange RAL 2003
YSLCY UL
![YSLCY UL - [GCE Cables - Italy]](/images/stories/cables/Special_Cables_for_Factory_Automation/YSLCY_UL.jpg)
![YSLCY UL - [GCE Cables - Italy]](/images/stories/cables/Special_Cables_for_Factory_Automation/YSLCY_UL_2.jpg)
Technical Data
Conductor resistance R 0,75 mm2 < 26,0 Ohm/km
1,00 mm2 < 19,5 Ohm/km
1,50 mm2 < 13,3 Ohm/km
2,50 mm2 < 7,98 Ohm/km
4,00 mm2 < 4,95 Ohm/km
6,00 mm2 < 3,30 Ohm/km
10,00 mm2 < 1,91 Ohm/km
Insulation resistance RI > 20 MOhm x km
Transfer impedance ZT < 250 mOhm/m
Operating voltage
power conductors U0/U 0,6/1 kV as per VDE
UB 1000 V as per UL
control conductors U0/U 300/500V as per VDE
UB 1000 V as per UL
Test voltage UT 4 kV (power conductors)
2 kV (control conductors)
Bending radius rmin. 10 x cable diameter
Temperature range
mobile application - 5 °C up to + 80 °C
fixed installation - 40 °C up to + 80 °C
Oil resistance IEC 60811-2-1
Flame retardance IEC 60332-1, EN 50265-2-1
Options
- other core configurations and cross
sections manufactured upon request - PUR trailing cables
- PUR trailing cables
with inner jacket - PUR trailing cables
low capacitance versions