PVC Servo Cables

Construction

A Conductor flexible bare copper as per IEC 60228 class 5
B Insulation PVC compound type TI2 with enhanced properties
B Identification power conductors black with printing U / L1 / C / L+, V / L2 resp.
B W / L3 / D / L-, green/yellow
B control conductors black number coded 5 - 8 for two pair con-
B struction, with printing BR1 resp. BR2 for one pair construction
C Screen polyester coated aluminium foil
D Drain wire tinned stranded copper
E Screen tinned copper braid, coverage approx. 85%
F Taping polyester foil
G Central filler flexible synthetic rope
G Cabling power conductors and pair(s) cabled in a concentric layer
G lateral fillers admitted
H Taping polyester foil
I Screen tinned copper braid, coverage approx. 85%
J Jacket special PVC compound type as per class 43
J Colour orange RAL 2003

YSLCY  UL

YSLCY UL - [GCE Cables - Italy]

YSLCY UL - [GCE Cables - Italy]

Technical Data

Conductor resistance                                 R               0,75 mm2 < 26,0   Ohm/km
                                                                                 1,00 mm2 < 19,5   Ohm/km
                                                                                 1,50 mm2 < 13,3   Ohm/km
                                                                                 2,50 mm2 <   7,98 Ohm/km
                                                                                 4,00 mm2 <   4,95 Ohm/km
                                                                                 6,00 mm2 <   3,30 Ohm/km
                                                                               10,00 mm2 <   1,91 Ohm/km
Insulation resistance                                 RI               > 20 MOhm x km
Transfer impedance                                  ZT               < 250 mOhm/m
Operating voltage
        power conductors                            U0/U           0,6/1 kV as per VDE
                                                              UB             1000 V as per UL
        control conductors                           U0/U          300/500V as per VDE
                                                              UB             1000 V as per UL
Test voltage                                             UT             4 kV (power conductors)
                                                                               2 kV (control conductors)

Bending radius                                       rmin.           10 x cable diameter

Temperature range
       mobile application                           -   5 °C up to + 80 °C
       fixed installation                              - 40 °C up to + 80 °C

Oil resistance                                        IEC 60811-2-1

Flame retardance                                  IEC 60332-1, EN 50265-2-1

 

Options

  • other core configurations and cross
    sections manufactured upon request
  • PUR trailing cables
  • PUR trailing cables
    with inner jacket
  • PUR trailing cables
    low capacitance versions